Product Details:

  • Measuring Range 0-10 kV
  • Frequency 50 Hz
  • Interface Type Standard Data Output
  • Mounting Type Benchtop
  • Humidity 20%-80% RH
  • Gas Pressure 0.6-0.8 MPa
  • Automation Grade Semi-automatic
X

EXstatic 312 Product Specifications

  • 0-500 mm
  • Room Temperature
  • Measurement of static electricity on samples
  • High Efficiency
  • 500 mm
  • AC 220V 50Hz
  • Static Charge Tester
  • 50 kg
  • Adjustable, up to 250 mm width
  • 220 V AC
  • 0.01 kV
  • <1 s
  • Multiple (Up to 5 at once)
  • Laboratory, Industrial
  • Semi-automatic
  • 0.6-0.8 MPa
  • Digital Display Control
  • 20%-80% RH
  • 50 Hz
  • 0-10 kV
  • Benchtop
  • Standard Data Output
  • 250 mm
  • Standard
  • Customizable
  • 5% F.S.
  • Anti-interference, Safe Operation, High Sensitivity
  • Large Digital LCD
  • Standard Speed Adjustable

Product Description

Advantage

  • Designed according to hygienic criteria
  • Surface finish Ra<0,78 or Ra<0,37
  • Stainless steel AISI 316L / 1.4404
  • EPDM sealings with FDA and USP VI approval
  • Process connections according to EHEDG / 3A
  • Optional sensor protection cage
  • Up to 10 bar and 140 C
  • Protection cap for cable connection

Specification

Process pressure:

010 bar
Process temperature: -10140 C
Material: 1.4404 / 316L
Surface: Ra<0,78 or Ra<0,37
Sealing material: EPDM / FDA / USP VI or FPM (Viton)
Material cable guard: PA6.6 GF30
Certificates: material, surface, sealing material
Option: with or without protection cage
Sensors: 120 mm 12 PG13,5
Process connections: Varivent N, Neumo BioControl D50


Advanced Static Charge Testing

Harnessing precise engineering, the EXstatic 312 excels in measuring static electricity on various materials. With a large, clear LCD display and digital control, users can fine-tune testing parameters such as stroke and speed. Its robust build and adjustable specimen size support high-throughput testing, making it a preferred choice in labs and industrial environments seeking repeatable, dependable results.


Seamless Data Handling and Export

The EXstatic 312 offers efficient internal data storage, simplifying workflow and ensuring data security. Results can be readily exported to CSV or TXT formats, enabling easy integration with most data analysis systems operating on Windows platforms. Standard ports and interface types further enhance connectivity, making reporting and archiving a straightforward process.


Enhanced Safety and Operational Reliability

Focused on user protection, the EXstatic 312 integrates an automatic stop function upon overload and robust anti-interference features. This ensures not only machine longevity but also operator safety during all testing scenarios. Its stable, benchtop design coupled with high sensitivity and fast response makes precise static charge detection both secure and reliable.

FAQs of EXstatic 312:


Q: How do I operate the EXstatic 312 for measuring static electricity on samples?

A: To operate the EXstatic 312, place your specimens (up to five at once with up to 250 mm width each) on the benchtop fixture, configure the desired parameters on the digital display control, and start the test. The machine will automatically measure the static charge within the customizable test range, displaying results on the large LCD.

Q: What data export formats are supported by the EXstatic 312?

A: The EXstatic 312 supports CSV and TXT data export formats. These can be downloaded from its internal memory for use in various data analysis software, ensuring compatibility with most Windows-based systems.

Q: When should I use the EXstatic 312s overload safety feature?

A: The overload safety feature operates automatically whenever the device detects excessive load or abnormal conditions during testing. This ensures both user safety and prevents equipment damage, requiring no manual intervention.

Q: Where can the EXstatic 312 be installed for optimal use?

A: This equipment is best suited for benchtop installation in laboratory or industrial environments. Ensure access to a standard AC 220V 50Hz power supply and maintain ambient room temperature and relative humidity between 20% and 80% for optimal performance.

Q: What is the process for exporting test results from the EXstatic 312?

A: After completing your tests, access the internal memory via the digital control interface. Select the required test data and export it in CSV or TXT format to a connected Windows-compatible device using the standard data output port.

Q: How does the EXstatic 312 benefit my static charge measurement workflow?

A: The EXstatic 312 delivers high-precision, fast static measurements, robust safety features, easy data export, and the capacity to test multiple specimens simultaneously. This improves efficiency, accuracy, and traceability in any measurement workflow.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top