Product Description
Application :
- Wastewater technology
- liquid level measurement
- pump control
- medical technology
- and many more
Technical data :
| Type | Setting range for upper switching point between | Maximum positive working pressure Standard/extended | Maximum negative working pressure Standard/extended |
| 901.61 | 5 and 20 mbar | 0,5/4 bar | /1 bar |
| 901.62 | 10 and 50 mbar | 0,5/4 bar | /1 bar |
| 901.63 | 25 and 100 mbar | 0,5/4 bar | /1 bar |
| 901.64 | 50 and 250 mbar | 1/4 bar | /1 bar |
| 901.65 | 100 and 500 mbar | 1/4 bar | /1 bar |
| 901.66 | 250 and 1.000 mbar | 10 bar | 1 bar |
| 901.67 | 500 and 1.500 mbar | 10 bar | 1 bar |
| 901.68 | 1.000 and 3.000 mbar | 10 bar | 1 bar |
| 901.91 | 1,0 and 6,0 bar | 25 bar | 1 bar |
| 901.92 | 4,0 and 9,0 bar | 25 bar | 1 bar |
| 901.93 | 7,0 and 12,0 bar | 25 bar | 1 bar |
| 901.71 | 5 and 20 mbar | 0,5/4 bar | 1 bar |
| 901.72 | 10 and 50 mbar | 0,5/4 bar | 1 bar |
| 901.73 | 25 and 100 mbar | 0,5/4 bar | 1 bar |
| 901.74 | 50 and 125 mbar | 0,5/4 bar | 1 bar |
| 901.75 | 75 and 200 mbar | 1/4 bar | 1 bar |
| 901.76 | 100 and 300 mbar | 1/4 bar | 1 bar |
| 901.77 | 200 and 500 mbar | 1/4 bar | 1 bar |
| 901.78 | 300 and 700 mbar | 1/4 bar | 1 bar |
| 901.81 | 5 and 20 mbar (differential pressure) | 100 mbar | 100 mbar |
| 901.82 | 10 and 50 mbar (differential pressure) | 100 mbar | 100 mbar |
Precision and Flexibility in Pressure ManagementThe 901 Prescal pressure switch delivers dependable performance in a variety of industrial environments. Adjustable set points and hysteresis ensure users can tailor the switchs operation to specific requirements. Robust construction and quality materials provide durability in demanding hydraulic and pneumatic settings, from factory automation to process control.
Engineered for Industrial ApplicationsWith its metal enclosure and IP54 rating, this switch is well-suited for tough conditions, resisting dust and splashes. The inclusion of a mounting bracket and G1/4 BSP threading supports straightforward installation on panels or machinery, ensuring hassle-free integration in air, oil, or water systems.
FAQs of Pressure switch 901 Prescal adjustable:
Q: How can the set point on the 901 Prescal pressure switch be adjusted?
A: The set point is easily adjustable using the external knob located on the enclosure, allowing users to select their desired activation pressure within the 1-10 bar range without disassembling the unit.
Q: What is the process for installing this pressure switch?
A: Installation involves panel mounting via the supplied bracket, connecting the process line using the G1/4 BSP thread, and wiring the screw terminals for electrical connection. Ensure adequate sealing using the nitrile rubber material provided for reliable operation.
Q: Where can this pressure switch be used for optimal results?
A: This switch is ideal for hydraulic and pneumatic systems requiring accurate pressure control. Its design is suited for use in industrial environments involving air, water, or oil, such as manufacturing plants, machinery, and process control setups.
Q: What benefits does the adjustable hysteresis offer?
A: The adjustable hysteresis feature allows users to fine-tune the switching differential, minimizing nuisance switching and extending the lifespan of connected devices by ensuring stable operation in fluctuating pressure environments.
Q: When is this pressure switch most effective?
A: It is particularly effective when quick and reliable pressure monitoring is crucial. The fast response time (<50 ms) and high accuracy (1.5% F.S.) enable prompt intervention in pressure changes, which is vital in sensitive industrial applications.
Q: What materials make up the enclosure and wetted parts?
A: The enclosure is constructed from powder-coated metal for robust protection, while pressure-contacting parts are made of engineering plastic, metal, and sealed with nitrile rubber to ensure chemical compatibility and durability.
Q: How does the IP54 protection rating benefit users?
A: The IP54 rating certifies resistance against dust ingress and water splashes, making the pressure switch reliable for operation in industrial or outdoor environments where such exposure is common.