Product Description
Applications :
- Building automation and air conditioning systems
- Overpressure measurement in clean rooms and laboratories
- Measurement of constant pressure in VAV applications
- Dynamic filter and ventilator monitoring
Technical data :
985M 2-wire with manual offset calibration
- Setting ranges:
Depending on type between -100 Pa and 1 bar - Temperature range:
Working and storage temperature from 20C to +70C - Process connection:
Hose connection with 4 / 6 mm outer diameter - Supply voltage:
18 to 30 VDC - Output signal:
4 20 mA - Electrical connection:
Plug-in terminals for wires and strands up to 1.5 mm2 or
circular connectors M12 / 4-pole - Protection class:
IP65 acc. to EN 60529
985M 3-wire with automatic offset calibration
- Setting ranges:
Depending on type between -100 Pa and 1 bar - Temperature range:
Working and storage temperature from 20C to +70C - Process connection:
Hose connection with 4 / 6 mm outer diameter - Supply voltage:
18 to 30 VDC - Output signal:
0 10 V
4 20 mA - Electrical connection:
Plug-in terminals for wires and strands up to 1.5 mm2 or
circular connectors M12 / 4-pole - Protection class:
IP65 acc. to EN 60529
985A 3-wire with automatic offset calibration
- Setting ranges:
Depending on type between -100 Pa and 1 bar - Temperature range:
Working and storage temperature from 10C to +50C - Process connection:
Hose connection with 4 / 6 mm outer diameter - Supply voltage:
18 to 30 VDC - Output signal:
0 10 V
4 20 mA - Electrical connection:
Plug-in terminals for wires and strands up to 1.5 mm2 or
circular connectors M12 / 4-pole - Protection class:
IP65 acc. to EN 60529
985Q 3-wire with automatic offset calibration
- Setting ranges:
Depending on type between -100 Pa and 1 bar - Temperature range:
Working and storage temperature from 10C to +50C - Process connection:
Hose connection with 4 / 6 mm outer diameter - Supply voltage:
18 to 30 VDC - Output signal:
0 10 V
4 20 mA - Electrical connection:
Plug-in terminals for wires and strands up to 1.5 mm2 or
circular connectors M12 / 4-pole - Protection class:
IP65 acc. to EN 60529
Reliable Performance for Industrial ApplicationsEngineered for the rigors of industrial settings, the Draft Pressure Transmitter 985 withstands environmental challenges thanks to its IP65-rated enclosure and solid build. Its accurate differential pressure measurement and rapid response time of less than 200 ms make it ideal for monitoring air and non-corrosive gases. With CE certification, users are assured of quality, compliance, and operational safety.
Versatile and Hassle-Free InstallationDesigned for easy integration, this transmitter offers flexible mounting optionspanel or surface mountsuitable for varied industrial uses. The supplied mounting bracket simplifies setup, while its compact size ensures it fits well within instrumentation panels. Its 1/4 BSP thread and NBR rubber seal maintain a tight, reliable connection in your processes.
FAQs of Draft Pressure Transmitter 985:
Q: How do I correctly install the Draft Pressure Transmitter 985?
A: For optimal performance, mount the transmitter vertically using the provided mounting bracket on either a panel or flat surface. Ensure that the 1/4 BSP threaded connections are properly sealed with the included NBR rubber material, and connect the 24V DC power supply before operation.
Q: What industries can benefit from using this pressure transmitter?
A: This transmitter is suitable for various industrial environments such as HVAC, cleanrooms, and process control systems where monitoring air and non-corrosive gas pressures is essential. Its CE marking, durable construction, and IP65 protection make it a reliable choice for demanding applications.
Q: When should I use the Draft Pressure Transmitter 985s overload limit?
A: It is designed to safely handle momentary exposure up to 120% of its full scale (1000 mmWC). This feature protects the sensor during unexpected pressure surges, ensuring continued accurate performance and preventing device damage.
Q: Where should I locate the transmitter for best accuracy?
A: For best results, install the device in a stable, vibration-free location within the specified operating temperature range (-10C to +60C). Ensure vertical mounting to preserve measurement accuracy and reduce potential installation-induced errors.
Q: What is the process for connecting the output signal to my monitoring system?
A: Connect the analog 4-20 mA output wires from the transmitter to your data acquisition or monitoring system following the wiring schematic provided in the manual. Use shielded cables to prevent signal interference for precise differential pressure readings.
Q: What are the primary benefits of the Draft Pressure Transmitter 985?
A: Users benefit from rapid response times (<200 ms), reliable measurement accuracy (1.6% F.S.), a robust and powder-coated die cast design, and simple integration into industrial control panels. The IP65 ingress protection and CE certification ensure durability and compliance with global standards.