Welcome to Our Company -

PM180 6-channel Modbus Pyrometer Hub with

PM180 6-channel Modbus Pyrometer Hub with

Product Details:

  • Type Pyrometer Hub
  • Theory Multi-channel temperature signal integration via Modbus
  • Capacity 6 Pyrometer Channels
  • Exterior Material Enclosure - Rugged Aluminum Alloy
  • Interior Material Electronic PCB Modules
  • External Size 172 mm x 65 mm x 110 mm (approx.)
  • Controller System Integrated Modbus RS485 PLC/SCADA Compatible
X

PM180 6-channel Modbus Pyrometer Hub with Product Specifications

  • Enclosure - Rugged Aluminum Alloy
  • 6 Pyrometer Channels
  • Pyrometer Hub
  • 172 mm x 65 mm x 110 mm (approx.)
  • Integrated Modbus RS485 PLC/SCADA Compatible
  • Multi-channel temperature signal integration via Modbus
  • Electronic PCB Modules

Product Description

General Specifications:

Attribute

Value

Compatibility

PyroMiniBus (all models), PyroBus (all models), PyroMini (-BB and -BRT models)

Display

2.83 (72 mm) resistive touch TFT, 320 x 240 pixels, backlit

Supply Voltage

10 to 30 V DC

Maximum Current Draw

100 mA

Ambient Temperature Range

0C to 60C

Relative Humidity

Maximum 95%, non-condensing

Configurable Parameters (global)

Temperature units, date and time, data logging, graph channels, alarm logging

Configurable Parameters (per sensor)

Signal processing, emissivity setting, reflected energy compensation, alarms, Modbus address

Alarm Configuration

12 alarms (2 per sensor) with adjustable level, individually configurable as HI or LO

Temperature Units

C or F selectable

Temperature Resolution

0.1

Signal Processing

Average, peak hold, valley hold, minimum, maximum

Display Sample Period

120 ms per sensor (720 ms in total for 6 sensors)

Data Logging Specifications:

Attribute

Value

Logging Interval

1 to 86,400 seconds (1 day)

MicroSD Card

Max. capacity: 32 GB (not included)

Internal Clock Battery

1 x BR 1225 3V (not included)

Variables Logged

Target temperature, sensing head temperature, alarm events

File Format

.csv (can be imported to Excel)

Configurable Parameters

Sample period, number of samples, scheduled start date and time

Mechanical Specifications:

Attribute

Value

Dimensions

98(w) x 64(h) x 36(d) mm excluding cable glands

Weight

280 g


 

 



Flexible and Efficient Integration

The PM180 hub provides six independent channels for connecting any pyrometer with Modbus output, making it easy to expand or scale your temperature monitoring system. Its reliable Modbus RTU RS485 communication supports high data rates up to 115200 baud, making it efficient for demanding industrial environments.


Robust Industrial Durability

Engineered with a strong aluminum alloy exterior and IP20-rated enclosure, the device withstands harsh environments. It operates between 0C and 50C and delivers dependable performance in both indoor and protected industrial applications.


Simplified Installation and Operation

Featuring DIN-rail or panel mounting, the PM180 hub offers flexibility for different setups, while per-channel LED indicators simplify troubleshooting and status checks. The device connects quickly via RS485 terminal blocks and is compatible with modern PLC and SCADA systems.

FAQ's of PM180 6-channel Modbus Pyrometer Hub with:


Q: How do I connect pyrometers to the PM180 6-channel Modbus Pyrometer Hub?

A: Each of the six independent channels can be connected to a compatible pyrometer with Modbus output using the RS485 terminal block. Follow the device's user manual for wiring specifics and ensure all Modbus addresses are configured correctly for communication.

Q: What types of pyrometers are supported by the PM180 hub?

A: The hub supports any pyrometer that outputs data via Modbus RTU protocol over RS485. This provides flexibility for integrating a variety of industrial temperature sensors from different manufacturers.

Q: When should I use a multi-channel pyrometer hub like the PM180 for my facility?

A: Use the PM180 hub when multiple temperature points require centralized monitoring and management, especially when integration with PLC/SCADA systems is needed for industrial process control or data logging.

Q: Where can the PM180 hub be installed within an industrial setup?

A: The PM180 hub can be mounted on a DIN rail inside control panels or directly on a panel, allowing for versatile placement in control rooms or near field devices, provided the area meets the IP20 protection requirements.

Q: What is the process for integrating the PM180 with my existing PLC or SCADA system?

A: After wiring your pyrometers to the hub, connect the RS485 output to your PLC or SCADA system's Modbus RTU interface. Configure the communication parameters, such as baud rate and device addresses, to match your system settings.

Q: How do the status LED indicators assist with usage?

A: Each input channel features an LED status indicator, providing a visual representation of channel activity. This allows quick diagnostics and helps users identify active or faulty channels without separate diagnostic tools.

Q: What are the key benefits of using the PM180 6-channel Modbus Pyrometer Hub?

A: The PM180 streamlines the integration and monitoring of multiple pyrometers, reduces wiring complexity, saves installation space, and ensures compatibility with industrial automation systems. Its rugged design and versatile mounting options make it suitable for diverse environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Infrared Temperature Sensors And Pyrometers' category