Product Description
Hazardous Area Classification:
| Specification | Value |
| ATEX Classification | Ex II 1GD |
| IECEx Classification (Gas) | Ex ia IIC T4 Ga |
| IECEx Classification (Dust) | Ex ia IIIC T135C IP65 Da |
| Ambient Temperature Rating | -20C Ta 70C |
| Maximum DC Input Voltage | Ui = 28 V |
| Maximum Input Current | Ii = 93 mA |
| Maximum Input Power | Pi = 650 mW |
| Maximum Internal Capacitance | Ci = 8 nF |
| Maximum Internal Inductance | Li = 0 mH |
| ATEX Certificate Number | CML 14ATEX2079 |
| IECEx Certificate Number | IECEx CML 14.0032 |
| JapanEx Certificate Number | CML 23JPN2141 |
| UKCA Certificate Number | CML 21UKEX2001 |
General Specifications:
| Specification | Value |
| Temperature Range | Configurable from -20C to 1000C via optional USB adapter; pre-set to a choice of ranges between these limits (see Ordering) |
| Maximum Temperature Span | 1000C |
| Minimum Temperature Span | 100C |
| Output | 4 to 20 mA |
| Optional USB configuration tool and RS-485 network interface available |
| Accuracy | 1C or 1%, whichever is greater |
| Repeatability | 0.5C or 0.5%, whichever is greater |
| Emissivity Setting Range | 0.20 to 1.00 (pre-set to 0.95) |
| Emissivity Setting Method | User configurable via optional modules |
| Response Time, t90 | 240 ms (90% response) |
| Spectral Range | 8 to 14 m |
| Supply Voltage | 12 to 24 V DC 5% |
| Maximum Current Draw | 25 mA |
| Maximum Loop Impedance | See Application Guide (available separately) |
Mechanical Specifications:
| Specification | Value |
| Construction | Stainless Steel 316 |
| Major Dimensions | 20 mm x length 150 mm (see Installation) |
| Mounting | M20 x 1.5 mm thread, length 46 mm, supplied with two mounting nuts |
| Cable Length | 5 m, 10 m, or 25 m as standard (custom lengths are also available) |
| Weight with 5 m Cable | 475 g |
Environmental Specifications:
| Specification | Value |
| Environmental Rating | IP65 (NEMA 4) |
| Ambient Temperature Range | 0C to 70C (Operating range) |
| Ambient Pressure Range | 80 kPa (0.8 bar) to 110 kPa (1.1 bar) |
| Relative Humidity | Max. 95% non-condensing |
| CE Marked | Yes |
| RoHS Compliant | Yes |
Precision Sensing in Hazardous AreasThe ExTemp Intrinsically Safe Temperature Sensor uses advanced infrared non-contact technology, providing reliable measurements in hazardous or explosive environments. Its intrinsic safety certification makes it suitable for use where flammable gases or dust are present, ensuring both safety and performance.
Robust Build and Easy InstallationConstructed from durable 316 stainless steel, this sensor offers superior resistance to corrosion and physical damage. With its compact design and threaded M20x1.5 mm body, installation is straightforward, even in confined or challenging industrial settings. The IP65 rating further protects against dust and water ingress.
Efficient Process IntegrationThe 2-wire, loop-powered 4-20 mA output enables seamless integration into standard industrial control systems. Its fast 240 ms response time and broad temperature range from -20C to +1000C make it ideal for dynamic process environments. The lack of a local display enhances reliability in hazardous areas.
FAQ's of ExTemp Intrinsically Safe for hazardous areas:
Q: How is the ExTemp Intrinsically Safe Temperature Sensor installed in hazardous areas?
A: The sensor is designed for easy installation using its threaded M20x1.5 mm body, which allows secure fitting onto process equipment. Its compact form and robust construction enable mounting even in tight spaces or harsh environments typically found in hazardous areas.
Q: What power supply and electrical connection does the ExTemp sensor require?
A: It operates using a 2-wire, loop-powered system, requiring a 12 to 30 VDC power supply. This configuration simplifies wiring and is widely compatible with standard industrial control infrastructure.
Q: When should the ExTemp sensor be used instead of a contact temperature sensor?
A: The ExTemp sensor is ideal when non-contact infrared measurement is required, such as with moving, inaccessible, or electrically live surfaces, or when the process involves hazardous or explosive atmospheres where direct contact is unsafe or impractical.
Q: Where can the ExTemp sensor be deployed in industrial environments?
A: It is suitable for use in any hazardous (potentially explosive) area, particularly in process industries such as chemical plants, oil refineries, and grain handling facilities, where intrinsic safety and non-contact temperature measurement are critical.
Q: What is the process for integrating the ExTemp sensor into a control system?
A: The sensor outputs a standard 4-20 mA analog signal, making it compatible with most PLCs, DCSs, and other process controllers. Simple two-wire loop wiring carries both power and signal, streamlining integration into existing systems.
Q: How does the ExTemp sensor benefit industrial applications?
A: It enhances safety by providing robust, non-intrusive temperature measurements in hazardous areas, reduces maintenance due to its sealed, rugged design, and delivers high accuracy (1%) over a wide temperature range, ensuring optimal process control.