Product Description
Hazardous Area Classification:
| Specification | Value |
| ATEX Classification | Ex II 1GD |
| IECEx Classification (Gas) | Ex ia IIC T4 Ga |
| IECEx Classification (Dust) | Ex ia IIIC T135C IP65 Da |
| Ambient Temperature Rating | -20C Ta 70C |
| Maximum DC Input Voltage | Ui = 28 V |
| Maximum Input Current | Ii = 93 mA |
| Maximum Input Power | Pi = 650 mW |
| Maximum Internal Capacitance | Ci = 8 nF |
| Maximum Internal Inductance | Li = 0 mH |
| ATEX Certificate Number | CML 14ATEX2079 |
| IECEx Certificate Number | IECEx CML 14.0032 |
| JapanEx Certificate Number | CML 23JPN2141 |
| UKCA Certificate Number | CML 21UKEX2001 |
General Specifications:
| Specification | Value |
| Temperature Range | Configurable from -20C to 1000C via optional USB adapter; pre-set to a choice of ranges between these limits (see Ordering) |
| Maximum Temperature Span | 1000C |
| Minimum Temperature Span | 100C |
| Output | 4 to 20 mA |
| Optional USB configuration tool and RS-485 network interface available |
| Accuracy | 1C or 1%, whichever is greater |
| Repeatability | 0.5C or 0.5%, whichever is greater |
| Emissivity Setting Range | 0.20 to 1.00 (pre-set to 0.95) |
| Emissivity Setting Method | User configurable via optional modules |
| Response Time, t90 | 240 ms (90% response) |
| Spectral Range | 8 to 14 m |
| Supply Voltage | 12 to 24 V DC 5% |
| Maximum Current Draw | 25 mA |
| Maximum Loop Impedance | See Application Guide (available separately) |
Mechanical Specifications:
| Specification | Value |
| Construction | Stainless Steel 316 |
| Major Dimensions | 20 mm x length 150 mm (see Installation) |
| Mounting | M20 x 1.5 mm thread, length 46 mm, supplied with two mounting nuts |
| Cable Length | 5 m, 10 m, or 25 m as standard (custom lengths are also available) |
| Weight with 5 m Cable | 475 g |
Environmental Specifications:
| Specification | Value |
| Environmental Rating | IP65 (NEMA 4) |
| Ambient Temperature Range | 0C to 70C (Operating range) |
| Ambient Pressure Range | 80 kPa (0.8 bar) to 110 kPa (1.1 bar) |
| Relative Humidity | Max. 95% non-condensing |
| CE Marked | Yes |
| RoHS Compliant | Yes |
Intrinsically Safe Sensing for Hazardous AreasExTemp is certified for use in ATEX and IECEx hazardous locations, making it an ideal choice for industries with flammable gases and dust. Its stainless steel construction and engineering allow for reliable performance even in demanding environments. The sensor's robust safety certifications help meet strict workplace safety requirements.
Exceptional Measurement PerformanceWith an impressive temperature range of -20C to 1000C and 1C or 1% accuracy, ExTemp provides precise results across extensive industrial processes. The rapid response time of 240 ms enables quick detection of temperature changes, crucial for process control and safety monitoring.
Durability and Protection in Extreme ConditionsDesigned for endurance, ExTemp boasts IP65 (NEMA 4) ingress protection and tolerates pressures up to 25 bar within the sensor housing. Its high-grade 316 stainless steel enclosure resists corrosion, ensuring long-term operation even in the toughest industrial settings.
FAQ's of ExTemp - Intrinsically Safe for hazardous areas:
Q: How is the ExTemp sensor installed in hazardous industrial environments?
A: The ExTemp sensor is typically installed using its compact sensor head (18mm diameter) and robust 1-metre cable, allowing easy integration into existing infrastructure. Ensure installation is performed by qualified personnel, following the ATEX and IECEx certification guidelines for hazardous areas.
Q: What is the measurement process of ExTemp in high-temperature applications?
A: ExTemp employs advanced non-contact infrared technology to detect temperatures quickly and accurately from surfaces at distances, capturing data within 240 ms. It transmits measurements via a 4-20mA loop-powered output, ensuring reliable monitoring without physical contact.
Q: When should ExTemp be used for temperature sensing in industrial environments?
A: ExTemp is ideal for continuous temperature monitoring in industries handling hazardous materials, such as oil, gas, chemicals, and mining. It's particularly valuable in processes requiring fast, safe, and accurate surface temperature readings in potentially explosive atmospheres.
Q: Where can the ExTemp sensor operate safely?
A: The sensor can be safely used in any hazardous zone certified under ATEX or IECEx, within ambient temperatures of -20C to 70C. Its enclosure allows operation in locations exposed to dust, water splashes, and moderate pressure environments up to 25 bar.
Q: What electrical protections does ExTemp include?
A: ExTemp features comprehensive electrical safety with protection against short circuits, reverse polarity, and over-voltage situations, safeguarding both the device and upstream control systems.
Q: How does ExTemp benefit industrial temperature monitoring?
A: ExTemp enhances safety by providing non-contact, intrinsically safe temperature readings in hazardous areas, minimizing operational risk while delivering accurate, real-time data for process optimization.